Volvo Twinpack generator set
800 to 1.267 kVA

Soundproofed in a special power generator container.

Volvo Penta Twinpack power generators 1.500 r.p.m and 1.800 r.p.m Diesel

800 bis 1.267 kVA Volvo Twinpack
Power generator
kVA 100 %
PRP*
Engine type
WA-V 800 C
800 TAD1344GE
WA-V 920 C
913 TAD1345GE
WA-V 1.000 C
1.000 TAD1641GE
WA-V 1.200 C
1.188 TAD1642GE
WA-V 1.280 C
1.267 TAD1643GE

*Prime Power PRP. Maximum power for variable load, no time limit per year. The average 24 hours operation should not exceed 80% of that power. For control purposes an thrust harder Maschinery is an overload of 10% for 1 hour within 12 hours permitted. Mode according to ISO 8528. The maintenace is to be considered.

Power and consumption Volvo Twinpack
Power generator Power
KWm.
Consumption
100 % Last PRP
WA-V 800 C
2 x 354 KW 163,00 L/h
WA-V 920 C
2 x 388 KW 181,00 L/h
WA-V 1.000 C
2 x 430 KW 203,00 L/h
WA-V 1.200 C
 2 x 503 KW 232,00 L/h
WA-V 1.280 C
2 x 536 KW 254,00 L/h
Tank capacity and length Volvo Twinpack
Power generator Tank capacity
in L
Length
in mm
WA-V 800 C
4.500 12.141
WA-V 920 C
4.500 12.141
WA-V 1.000 C
4.500 12.141
WA-V 1.200 C
4.500 12.141
WA-V 1.280 C
4.500 12.141
Width and height Volvo Twinpack
Power generator Width
in mm
Height
in mm
WA-V 800 C
2.432 2.585
WA-V 920 C
2.432 2.585
WA-V 1.000 C
2.432 2.585
WA-V 1.200 C
2.432 2.585
WA-V 1.280 C
2.432 2.585

Basic equipment Volvo Penta power generator 

Reference conditions

1.000 mbar, 25°C, 30% relative humidity. Performance according to ISO 3046th.

Power generator

The complete power generatorset is mounted on a steel base frame. On the steel base frame are specially designed devices, for lifting with a crane or Forklift. The diesel engine and the alternator are connected to a SAE-flange, that even a longer period of operation no possibility of an adjustment exists. The daily fuel tank is integrated in the steel base frame. The starter batteries of 12 or 24 volts are fixed on the steel base frame. Preheating-system 230 Volt DC.

Engine

Volvo industrial diesel 4-stroke direct injection, watercooled 1.500 rpm (50 Hz). Low oil and fuel consumption with long maintenance intervals make a very economic engine application.

Alternator

Mecc Alte alternator, brushless self-exciting, self-regulating with electronic voltage regulator (AVR) according to VDE 0530, 400/230 volts, 4-pole, insulation class H.

Control Panel

Manual start-stop-system with engine shutdown during monitoring, when low oil pressure (LOP), High temperate (HWT) and overspeed. Alternator switch, 3-pole with thermal and magnetic protection. Frequency meter, hours counter, voltmeter, ampere meter, optical and acoustic alarm. Electronic engine speed governor, AMF automatic control panel with ATS, for parallel operation with the mains supply or peak looping operation.

Options

For all power generator is a wide range of accessories available.

Technical changes

We keep ahead.

All specified data “Volvo generator” included in standard delivery.

We are pleased to answer your questions


    I have read and understood the privacy policy. I agree that my details and data will be collected and stored electronically for the purpose of responding to my enquiry. Please note: You can revoke your consent at any time by sending an email to info@wa-strom.com.